CYLINDRIC IMPLANTS – BOLERO – SPECIFICIATIONS

tb-cylindric-implant-

IMPLANTS CYLINDRIQUES – BOLERO

classic-implant2

MSI France Cylindric Implants Bolero are Titanium parallel type Implants, with an internal hexagon connection.

They are designed for both single-stage or double-stage procedures.

MSI France Cylindric Implants design includes a unique wide-thread as well as tapered threads at the apical part.

Features:

  • Suits a wide range of bone types and bone augmentation procedures.
  • Wide range of restoration parts.
  • Self-tapping with, threads that are designed to provide secure primary fixation
  • Double thread of 1,2 mm
  • Three spiral channels for improved integration (1)
  • Micro rings on the implants neck optimize the shear strengths in the crest zone (1)
  • Aggressive apex with three cutting

Range :

The Cylindric Implant Bolero is available in 3.5 mm diameter and in lengths of 10,11.5,13 and 16mm.

Surface:

The surface roughness and microgeometry of commercially pure titanium grade 5 are achieved by sand blasting. Blasted surfaces demonstrate more bone-to-implant surface contact, compared to machined surfaces. In several clinical studies it has been demonstrated that sand blasted implant have excellent survival rate (between 96,9% to 100%) (2-5)

Self-Tapping:

The three cutting flutes are designed to engage the bone immediately during placement and ensure multidirectional locking. The tapping head cuts into the bone with far less friction due to the relief design of the cutting edge

CE0120

Sterile class IIb Medical Device.
For any additional information please carefully read related product instruction for use and labelling.

(1) C M. Stanford. Surface Modification of Biomedical and Dental Implants and the Processes of Inflammation, Wound Healing and Bone Formation. Int. J. Mol. Sci. 2010;11:354-69.
(2) L. Rasmusson. A 10-year follow-up study of titanium dioxide-blasted implants. Clin Implant Dent Relat Res. 2005;7(1):36-42.
(3) B. Collaert. Immediate functional loading of TiOblast dental implants in full-arch edentulous maxillae: a 3-year prospective study. Clin Oral Implants Res. 2008;19(12):1254-60.
(4) Astrand P. Astra Tech and Brånemark system implants: a 5-year prospective study of marginal bone reactions. Clin Oral Implants Res. 2004;15(4):413-20.
(5) Cooper L. A multicenter 12-month evaluation of single-tooth implants restored 3 weeks after 1-stage surgery. Int J Oral Maxillofac Implants. 2001;16(2):182-92.